Hewlett Packard Enterprise A5500-48G-PoE EI Switch **New  (JD376A)

Hewlett Packard Enterprise A5500-48G-PoE EI Switch **New

3 124:-
3 905:- inkl. moms

SKU: JD376A
Produkt:
Ethernet PoE
Portar:
48
Hastighet:
1Gbps

These Gigabit Ethernet switches deliver outstanding security, reliability, and multiservice support capabilities for robust switching at the edge or aggregation layer of large enterprise and campus networks or in the core layer of SMB networks. The HP A5500G EI Switch Series is comprised of Layer 2/3 Gigabit Ethernet switches that can accommodate the most demanding applications and provide resilient and secure connectivity as well as the latest traffic prioritization technologies to enhance applications on convergent networks. With complete IPv4/IPv6 dual stack support, the series provides investment protection with an easy transition from IPv4 to IPv6 networks. Designed for increased flexibility, these switches are available with 24 or 48 Gigabit Ethernet ports. Power over Ethernet (PoE) and non-PoE models are available with optional GbE and 10 GbE expansion capability. The all-fiber model with dual power supplies is ideal for applications that require the highest availability.

Quality of Service (QoS)

• Storm restraint: allows limitation of broadcast, multicast, and unknown unicast traffic rate to cut down on unwanted broadcast traffic on the network


Management

• Friendly port names: allow assignment of descriptive names to ports


Connectivity

• Auto-MDIX: automatically adjusts for straight-through or crossover cables on all 10/100/1000 ports


Performance

• Nonblocking architecture: up to 176 Gbps nonblocking switching fabric provides wire-speed switching with up to 130 million pps throughput


Resiliency and high availability

• Separate data and control paths: keeps control separated from services and keeps service processing isolated; increases security and performance


Layer 2 switching

• 32K MAC addresses: provide access to many Layer 2 devices


Layer 3 services

• Address Resolution Protocol (ARP): determines the MAC address of another IP host in the same subnet

Överensstämmelse med medicinska standarder
Elektromagnetisk kompatibilitet
FCC part 15 Class A; VCCI Class A; EN 55022 Class A; CISPR 22 Class A; ICES-003 Class A; ANSI C63.4 2003; ETSI EN 300 386 V1.3.3; AS/NZS CISPR22 Class A; EN 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6; EN 61000-4-11; EN 61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A
Säkerhet
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; EN 60950-1/A11; FDA 21 CFR Subchapter J; ROHS Compliance
Allmänna protokoll
Värmeavgivning
921 BTU/hr (971.66 kJ/hr)
Routingtabellstorlek
12000 entries
Kapacitet för routing/switching
192 Gbps
Administrationsfunktioner
IMC - Intelligent Management Center; command-line interface; Web browser; SNMP Manager; IEEE 802.3 Ethernet MIB
BGP
RFC 1657 Definitions of Managed Objects for BGPv4; RFC 1771 BGPv4; RFC 2858 BGP-4 Multi-Protocol Extensions
Enhetsadministration
RFC 1157 SNMPv1/v2c; RFC 1305 NTPv3; RFC 1901 (Community based SNMPv2); RFC 2452 MIB for TCP6; RFC 2454 MIB for UDP6; RFC 2573 (SNMPv3 Applications); RFC 2576 (Coexistence between SNMP V1, V2, V3); RFC 2819 RMON; RFC 3410 (Management Framework); RFC 3416 (SNMP Protocol Operations v2); RFC 3417 (SNMP Transport Mappings); HTML and telnet management; Multiple Configuration Files; SNMP v3 and RMON RFC support; SSHv1/SSHv2 Secure Shell
Allmänna protokoll
IEEE 802.1ad Q-in-Q; IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q (GVRP); IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ab 1000BASE-T; IEEE 802.3ad Link Aggregation (LAG); IEEE 802.3ae 10-Gigabit Ethernet; IEEE 802.3af Power over Ethernet; IEEE 802.3i 10BASE-T; IEEE 802.3u 100BASE-X; IEEE 802.3x Flow Control; IEEE 802.3z 1000BASE-X; RFC 768 UDP; RFC 791 IP; RFC 792 ICMP; RFC 793 TCP; RFC 854 TELNET; RFC 925 Multi-LAN Address Resolution; RFC 950 Internet Standard Subnetting Procedure ; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1122 Host Requirements; RFC 1141 Incremental updating of the Internet checksum; RFC 1213 Management Information Base for Network Management of TCP/IP-based internets; RFC 1305 NTPv3; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 1723 RIP v2; RFC 1812 IPv4 Routing; RFC 1887 An Architecture for IPv6 Unicast Address Allocation; RFC 2131 DHCP; RFC 2236 IGMP Snooping; RFC 2338 VRRP; RFC 2375 IPv6 Multicast Address Assignments; RFC 2616 HTTP Compatibility v1.1; RFC 2644 Directed Broadcast Control; RFC 2865 Remote Authentication Dial In User Service (RADIUS); RFC 2866 RADIUS Accounting; RFC 3246 Expedited Forwarding PHB; RFC 3410 Applicability Statements for SNMP; RFC 3414 User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3); RFC 3415 View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP); RFC 3417 Transport Mappings for the Simple Network Management Protocol (SNMP); RFC 3484 Default Address Selection for Internet Protocol version 6 (IPv6); RFC 3493 Basic Socket Interface Extensions for IPv6; RFC 3542 Advanced Sockets Application Program Interface (API) for IPv6; RFC 3587 IPv6 Global Unicast Address Format; RFC 3596 DNS Extensions to Support IP Version 6; RFC 3623 Graceful OSPF Restart; RFC 3704 Unicast Reverse Path Forwarding (URPF); RFC 3768 VRRP; RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6; RFC 4113 Management Information Base for the User Datagram Protocol (UDP); RFC 4213 Basic IPv6 Transition Mechanisms; RFC 4443 Internet Control Message Protocol (ICMPv6) for the Internet Protocol Version 6 (IPv6) Specification; 802.1r - GARP Proprietary Attribute Registration Protocol (GPRP)
IP Multicast
RFC 2236 IGMPv2; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2858 Multiprotocol Extensions for BGP-4; RFC 3376 IGMPv3; RFC 3569 An Overview of Source-Specific Multicast (SSM); RFC 3618 Multicast Source Discovery Protocol (MSDP); RFC 3973 PIM Dense Mode; RFC 4601 PIM Sparse Mode
IPv6
RFC 1881 IPv6 Address Allocation Management; RFC 1887 IPv6 Unicast Address Allocation Architecture; RFC 1981 IPv6 Path MTU Discovery; RFC 2080 RIPng for IPv6; RFC 2373 IPv6 Addressing Architecture; RFC 2375 IPv6 Multicast Address Assignments; RFC 2460 IPv6 Specification; RFC 2461 IPv6 Neighbor Discovery; RFC 2462 IPv6 Stateless Address Auto-configuration; RFC 2463 ICMPv6; RFC 2464 Transmission of IPv6 over Ethernet Networks; RFC 2475 IPv6 DiffServ Architecture; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2740 OSPFv3 for IPv6; RFC 2893 Transition Mechanisms for IPv6 Hosts and Routers; RFC 2925 Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations (Ping only); RFC 2925 Remote Operations MIB (Ping only); RFC 3056 Connection of IPv6 Domains via IPv4 Clouds; RFC 3162 RADIUS and IPv6; RFC 3306 Unicast-Prefix-based IPv6 Multicast Addresses; RFC 3307 IPv6 Multicast Address Allocation; RFC 3315 DHCPv6 (client and relay); RFC 3484 Default Address Selection for IPv6 ; RFC 3493 Basic Socket Interface Extensions for IPv6; RFC 3513 IPv6 Addressing Architecture; RFC 3542 Advanced Sockets API for IPv6; RFC 3587 IPv6 Global Unicast Address Format; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 for IPv6; RFC 4113 MIB for UDP; RFC 4443 ICMPv6
MIB
RFC 1212 Concise MIB Definitions; RFC 1213 MIB II; RFC 1657 BGP-4 MIB; RFC 1724 RIPv2 MIB; RFC 1757 Remote Network Monitoring MIB; RFC 1850 OSPFv2 MIB; RFC 2012 SNMPv2 MIB for TCP; RFC 2013 SNMPv2 MIB for UDP; RFC 2233 Interface MIB; RFC 2452 IPV6-TCP-MIB; RFC 2454 IPV6-UDP-MIB; RFC 2465 IPv6 MIB; RFC 2466 ICMPv6 MIB; RFC 2571 SNMP Framework MIB; RFC 2572 SNMP-MPD MIB; RFC 2573 SNMP-Target MIB; RFC 2574 SNMP USM MIB; RFC 2618 RADIUS Authentication Client MIB; RFC 2620 RADIUS Accounting Client MIB; RFC 2787 VRRP MIB; RFC 2819 RMON MIB; RFC 2925 Ping MIB; RFC 3414 SNMP-User based-SM MIB; RFC 3415 SNMP-View based-ACM MIB; RFC 4113 UDP MIB
Nätverkshantering
IEEE 802.1AB Link Layer Discovery Protocol (LLDP); IEEE 802.1D (STP); RFC 1157 SNMPv1; RFC 1212 Concise MIB definitions; RFC 1215 SNMP Generic traps; RFC 1757 RMON 4 groups: Stats, History, Alarms and Events; RFC 1901 SNMPv2 Introduction; RFC 1918 Private Internet Address Allocation; RFC 2373 Remote Network Monitoring Management Information Base for High Capacity Networks ; RFC 2571 An Architecture for Describing SNMP Management Frameworks; RFC 2572 Message Processing and Dispatching for the Simple Network Management Protocol (SNMP) ; RFC 2573 SNMP Applications; RFC 2574 SNMPv3 User-based Security Model (USM); RFC 2575 SNMPv3 View-based Access Control Model (VACM); RFC 2576 Coexistence between SNMP versions; RFC 2578 SMIv2; RFC 2581 TCP6; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 2925 Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations ; RFC 3176 sFlow; RFC 3410 Introduction to Version 3 of the Internet-standard Network Management Framework ; RFC 3414 SNMPv3 User-based Security Model (USM); RFC 3415 SNMPv3 View-based Access Control Model VACM); ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3
OSPF
RFC 1587 OSPF NSSA; RFC 1850 OSPFv2 Management Information Base (MIB), traps; RFC 2328 OSPFv2; RFC 3623 Graceful OSPF Restart
QoS/Cos
IEEE 802.1P (CoS); RFC 2474 DSCP DiffServ; RFC 2475 DiffServ Architecture; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF)
Säkerhet
IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 1918 Address Allocation for Private Internets; RFC 2865 RADIUS Authentication; RFC 2866 RADIUS Accounting; Access Control Lists (ACLs); MAC Authentication; Port Security; SSHv2 Secure Shell
Latens
1000 Mb Latency: < 3.2 µs; 10 Gbps Latency: < 2.6 µs
Genomströmning
142.9 million pps
Portar
48 RJ-45 autosensing 10/100/1000 PoE ports(IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3af PoE), Media Type: Auto-MDIX, Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only; 4 dual-personality ports, autosensing 10/100/1000BASE-T or SFP; 2 port expansion module slots; 1 RJ-45 serial console port; Supports a maximum of 48 autosensing 10/100/1000 ports
Ljudtryck (standby)
Luftfuktighet vid drift
10 to 90% (noncondensing)
Luftfuktighet vid förvaring
5 to 95% (noncondensing)
Driftstemperatur
0 to 45°C
Driftstemperatur
32 to 113°F
Förvaringstemperatur
-40 to 70°C
Förvaringstemperatur
-40 to 158°F
Friskrivning
Friskrivningsklausul
Product image may differ from actual product
Palldimensioner
Minimimått (B x D x H)
42 x 44 x 4.36 cm
Kartongens vikt (kartong eller ytterförpackning)
Vikt
6.5 kg
Garantialternativ
Garanti
Lifetime, advance replacement, next business day, phone support, software releases
Processorkärna (facet)
Minne och processor
256 MB SDRAM, packet buffer size: 4 MB, 32 MB flash
Batterityp
Strömförsörjning
With AC input, the maximum power consumption is 640 W (370 W for PoE).
Strömförbrukning
910 W (maximum)
Infrekvens
50/60 Hz
Inspänning
100-240 VAC; -52 to -55 VDC (depending on power supply chosen)
Rörgänga
Strömförsörjning, PoE
740 W
Montering
Mounts in an EIA standard 19-in. telco rack or equipment cabinet (hardware included)
Fläktbrickor
Format
1U height
DATORUTRUSTNING / KABLAR / KABLAR
Även om vi gör vårt bästa för att ge relevant information, så är bilderna bara till för att ge ett generellt intryck, och själva varan behöver nödvändigtvis inte se ut precis som på bilden. Om det är skillnader mellan produktöverskrift, beskrivning och bild, så är det produktöverskriften som gäller. (tex. Pc:n kommer inte nödvändigtvis med monitor även om bilden visar det) Om något är oklart skicka en e-post till oss före du beställer! Vi förbehåller oss för tryckfel, ändringar av priser och specifikationer utan varsel.